Humidity Converter

Convert between relative humidity, absolute humidity, specific humidity, dew point, and vapor pressure.

Definition: Absolute humidity is the mass of water vapour per unit volume of air, expressed in g/m³. Relative humidity is the ratio of the actual vapour pressure to the saturation vapour pressure at the same temperature, expressed as a percentage.

AMS Glossary of Meteorology Last updated: 2026-11

Relative Humidity Calculator


                    

RH is relative humidity; AH is vapor mass per volume; q is vapor mass per total moist-air mass. q differs from the mixing ratio (vapor mass per dry-air mass). The saturation equations follow Ambaum (2020), with MetPy 1.7.1 constants and explicit liquid/ice selection. The numerical input range is −80 to +50 °C; subzero liquid-water results are a model extrapolation, not an accuracy guarantee. A zero RH has no finite dew point; dew/frost points below −80 °C are outside the display range. MetPy

Humidity Level Reference

30% - 50%
Comfortable for most people
50% - 60%
Slightly humid, still comfortable
60% - 70%
Humid, may feel muggy
Above 70%
Very humid, uncomfortable
Below 30%
Dry, may cause irritation
Below 20%
Very low relative humidity

Comfort Level

Comfortable
Moisture-control reference; individual comfort varies.

Current Status

Indoor Humidity

About Humidity

  • Relative Humidity: Moisture in air vs maximum capacity
  • Dew Point: Temperature where air becomes saturated
  • Ideal Indoor: 30% - 50% relative humidity

How to Use the Humidity Calculator

1

Enter Temp

Input the current temperature in Celsius

2

Enter Humidity

Input relative humidity percentage (0-100%)

3

View Dew Point

See calculated dew point temperature

4

Check Comfort

Use reference guide for comfort levels

Understanding Humidity & Dew Point

What is Dew Point?

Dew point is the temperature at which air becomes saturated with water vapor, causing dew to form. It's a more accurate measure of atmospheric moisture comfort than relative humidity alone.

  • • Relative Humidity: Percentage of moisture in air vs capacity
  • • Dew Point: Temperature where condensation occurs
  • • Comfort Index: How humidity affects human comfort
  • • Health Impact: Effects on respiratory conditions

Why Monitor Humidity?

Proper humidity levels are crucial for health, comfort, and preserving property. Too dry causes irritation and damage; too humid promotes mold and discomfort.

  • • Health: Humidity preferences vary; indoor moisture control does not guarantee health protection
  • • Home Comfort: Prevent muggy or dry indoor conditions
  • • Property Protection: Avoid mold or excessive dryness damage
  • • Weather Planning: Understand outdoor comfort conditions

Instant Calculation

Real-time dew point calculation as you enter values.

100% Private

All calculations in your browser. No data stored or transmitted.

Completely Free

No registration or limits. Calculate humidity freely.

Humidity Conversion Formulas

Dew point / frost point: inverse vapor pressure

e = (RH / 100) × es(T); solve es(Tpoint) = e

Saturation pressure uses the selected water or ice model from Ambaum (2020), equations 13 and 17, with constants matching MetPy 1.7.1. The point is solved numerically from the same model. Water gives dew point; ice gives frost point. Zero vapor pressure has no finite point. Points below the supported −80 °C calculation range are not reported; this is not an instrument accuracy guarantee.

Where T is air temperature in °C, RH is relative humidity in %, and a = 17.27 and b = 237.7 °C are Magnus coefficients. The formula is accurate to within about 0.35 °C for temperatures from −40 °C to +50 °C, which covers virtually all practical weather and indoor conditions.

Absolute Humidity

AH (g/m³) = 1000 × e (Pa) / [Rv × (273.15 + T)]

Absolute humidity is the water vapor mass per volume of air. e is vapor pressure in pascals, Rv ≈ 461.52 J/(kg·K), and T is temperature in Celsius. RH is defined relative to saturation over the selected phase.

Specific Humidity & Vapor Pressure

q (g/kg) = 1000 × εe / [P − (1 − ε)e]; ε ≈ 0.622

Specific humidity q is water vapor mass divided by total moist air mass. P and e must use the same pressure unit. Do not confuse q with dry-air mixing ratio εe/(P−e). Change P to the pressure at your location; 1013.25 hPa is a reference value. Heating without adding or removing moisture changes RH, while q remains constant.

Where Humidity Conversion Matters

HVAC & Building Management

The EPA recommends indoor relative humidity below 60%, ideally 30–50%, alongside fixing leaks and drying wet materials. This reduces moisture risk but does not guarantee that mold cannot grow. Compare dew point with surface temperatures to assess condensation risk.

Weather & Meteorology

Dew point is the most direct measure of how humid the air feels. A dew point below 10 °C feels dry and crisp, 10–16 °C is comfortable, 16–20 °C noticeably humid, and above 20 °C feels muggy — above 24 °C is oppressive for most people. Forecasters track dew point to predict fog, frost, and thunderstorm potential.

Industry & Manufacturing

Painting, electronics assembly, pharmaceutical production, and food processing all specify strict humidity ranges. Too much moisture ruins powder coating and causes corrosion; too little causes brittle materials and static discharge that damages semiconductors. Absolute humidity in g/m³ is used to specify drying and storage conditions.

Agriculture & Storage

Storage and greenhouse targets depend on the crop, temperature, material and process. This converter calculates humidity quantities; it does not establish safe food-storage limits or certify the absence of mold or mycotoxins.

Frequently Asked Questions

What is the difference between relative humidity and absolute humidity?

Relative humidity (RH) expresses moisture as a percentage of the maximum amount of water vapor the air can hold at its current temperature, so it changes when temperature changes. Absolute humidity (AH) is the actual mass of water vapor per cubic meter of air (g/m³), and specific humidity is the mass of water vapor per kilogram of moist air (g/kg). At 25 °C and 50% RH, the absolute humidity is about 11.5 g/m³.

What dew point is considered comfortable?

A dew point below 10 °C feels dry, 10–16 °C feels comfortable, 16–20 °C is noticeably humid, and above 20 °C feels muggy. Dew point above 24 °C is oppressive for most people. Unlike relative humidity, dew point directly measures the actual amount of moisture in the air, which is why meteorologists use it to describe how the weather feels.

How accurate is the Magnus dew point formula?

The Magnus-Tetens approximation used by this calculator is accurate to within about 0.35 °C for temperatures from −40 °C to +50 °C and relative humidity above 5%. For most weather, HVAC, and industrial applications this is well within acceptable tolerance. Laboratory-grade applications may require a psychrometric chart or exact steam-table equations.

Can relative humidity exceed 100%?

In clean air, RH above 100% causes condensation immediately. However, supersaturation up to about 101–102% can briefly exist when there are no condensation nuclei (dust or particles) present, which happens in clouds and in laboratory conditions. Values above 102% from a home sensor usually indicate sensor error.

Why does indoor humidity drop in winter?

Cold outdoor air holds very little moisture — air at −5 °C and 80% RH contains roughly 2.8 g/m³ of water vapor. When that air enters your home and warms to 22 °C, the same moisture equals only about 15% relative humidity. This is why indoor RH often falls below 25% in winter, causing dry skin, static shocks, and cracked wood — a humidifier can restore the 30–50% comfort range.

How do I convert dew point back to relative humidity?

Rearranging the Magnus formula: RH = 100 × exp((a × Td)/(b + Td) − (a × T)/(b + T)), where T is air temperature and Td is dew point. As a rule of thumb, when temperature and dew point are equal, RH is exactly 100% — the closer they are, the higher the humidity.

How do I convert a thermometer and hygrometer reading into other humidity units?

Enter the air temperature and relative humidity from your instruments, and the calculator converts them to dew point, absolute humidity, specific humidity, and vapor pressure at once. For example, 25 °C at 60% RH corresponds to a dew point of about 16.7 °C and an absolute humidity of about 13.8 g/m³. Entering a dew point instead works in reverse to give relative humidity.

Is there a humidity conversion table I can check?

As a reference point: at 25 °C and 50% RH, absolute humidity is about 11.5 g/m³, specific humidity about 9.9 g/kg, vapor pressure about 1.59 kPa, and dew point about 13.9 °C. For other temperatures and humidities, enter your values above — the tool converts all units together, which is more precise than a static table with rounded rows.

Will the calculator remember my last inputs?

Yes. The values you enter are saved in your browser's local storage and restored automatically the next time you open this tool, so a refresh or an accidental close never loses your work. Nothing is uploaded — the saved inputs stay on your device, and clearing your browser data resets them.

Convert between different units of measurement